PCD Series0403 ±20% 3.3μH 0.086 Ω 2A
Größe | Toleranz | Induktivität | Testbedingungen | DCR (Ω) max. | IDC (A) |
---|---|---|---|---|---|
0403 | ±20% | 3.3 | 100KHz, 0.25V | 0.086 | 2 |
Type | Tape Size | Parts Per Reel | |
---|---|---|---|
W | P | 13" | |
PCD0301 | 12 | 8 | 3000 |
PCD0302 | 12 | 8 | 2000 |
PCD0403 | 12 | 8 | 1500 |
PCD0502 | 12 | 8 | 2000 |
PCD0503 | 12 | 8 | 1500 |
PCD0504 | 12 | 8 | 1500 |
PCD0703 | 16 | 12 | 1000 |
PCD0705 | 16 | 12 | 1000 |
PCD1004 | 24 | 12 | 1000 |
PCD1005 | 24 | 12 | 500 |
PCD1006 | 24 | 12 | 500 |
General
Item | Specification |
---|---|
Shelf Storage conditions | Temperature range: 15 ~ 28°C; Humidity: < 80% relative humidity. Recommended product should be used within one year from the time of delivery. |
Environmental Test
Item | Specification | Test Conditions / Test Methods |
---|---|---|
High temperature Storage test | No case deformation or change in appearance. Δ L/L ≤10% |
Temperature 85 ± 2°C, Time: 48 ± 2 hours, Tested after 1hour at room temperature. |
Low temperature Storage test | Temperature -25 ± 2°C, Time: 48 ± 2 hours, Tested after 1hour at room temperature. |
|
Humidity test | Temperature 40 ± 2°C, 90~95% relative humidity Time: 96 ± 2 hours Tested after 1hour at room temperature. |
|
Thermal shock test | First -25°C 30minutes then 25°C 10 minutes last 85°C 30 minutes, as 1 cycle. Go through 5 cycles. Tested after 1 hour at room temperature. |
Mechanical Test
Item | Specification | Test Conditions / Test Methods |
---|---|---|
Solderability test | Terminal area must have 90% minimum solder coverage. | Dip pads in flux then dip in solder pot (SnCuNi) at 245 ± 5°C for 3 seconds. |
Resistance to Soldering Heat | No case deformation or change in appearance. | Flux should cover the whole of the sample before heating, then be preheated for about 2 minutes over temperature of 130 ~ 150°C. Immersing to 260 ± 5°C for 10 seconds. |
Vibration test | No case deformation or change in appearance. Δ L/L ≤10% |
Apply frequency 10 ~ 55Hz. 1.5mm amplitude in each of perpendicular direction for 2 hours. |
Shock resistance | Drop down with 981m/s² (100G) shock attitude upon a rubber block method shock testing machine, for 1 time. In each of three orientations. |
The Condition Of Reflow (Recommendation):