SMD 전원 인덕터 (SDIA 시리즈 SDIA0410NT1R0)
SDIA0410NT1R0
SMD 소형 파워 인덕터, 작은 크기와 낮은 프로파일, 높은 전류에 대응하며 자기로 보호되는 방패 구조. LCD 디스플레이, DC-DC 컨버터, PDA의 작은 크기에 대한 충격에 강한 구조.
SDIA Series0410 ±30% 1μH 0.1 Ω 1.8A
크기 | 허용오차 | 인덕턴스 | 테스트 조건 | DCR (Ω) 최대. | IDC (A) |
---|---|---|---|---|---|
0410 | ±30% | 1 | 100KHz, 0.25V | 0.1 | 1.8 |
테이프 및 릴 사양 (단위: mm)
Type | Tape Size | Parts Per Reel | ||
---|---|---|---|---|
W | P | 7" | 13" | |
SDIA0310 | 8 | 4 | 2000 | - |
SDIA0312 | 8 | 4 | 2000 | - |
SDIA0315 | 8 | 4 | 2000 | - |
SDIA0410 | 12 | 8 | - | 5000 |
SDIA0412 | 12 | 8 | - | 4500 |
SDIA0415 | 12 | 8 | - | 3000 |
SDIA0418 | 12 | 8 | - | 3000 |
SDIA0420 | 12 | 8 | - | 3000 |
SDIA0430 | 12 | 8 | - | 2500 |
SDIA0520 | 12 | 8 | - | 2500 |
SDIA0540 | 12 | 8 | - | 1500 |
SDIA0620 | 12 | 8 | - | 2000 |
SDIA0628 | 16 | 8 | - | 1500 |
SDIA0645 | 16 | 12 | - | 1000 |
SDIA0840 | 16 | 12 | - | 1000 |
SMT 전원 인덕터 환경 사양
General
Item | Specification |
---|---|
Shelf Storage conditions | Temperature range: 15 ~ 28°C; Humidity: < 80% relative humidity. Recommended product should be used within 12 months from the time of delivery. |
Environmental Test
Item | Specification | Test Conditions / Test Methods |
---|---|---|
High temperature Storage test | No case deformation or change in appearance. Δ L/L ≤10% |
Temperature 85 ± 2°C, Time: 48 ± 2 hours, Tested after 1hour at room temperature. |
Low temperature Storage test | Temperature -25 ± 2°C, Time: 48 ± 2 hours, Tested after 1hour at room temperature. |
|
Humidity test | Temperature 40 ± 2°C, 90~95% relative humidity Time: 96 ± 2 hours Tested after 1hour at room temperature. |
|
Thermal shock test | First -25°C 30minutes then 25°C 10 minutes last 85°C 30 minutes, as 1 cycle. Go through 5 cycles. Tested after 1 hour at room temperature. |
Mechanical Test
Item | Specification | Test Conditions / Test Methods |
---|---|---|
Solderability test | Terminal area must have 90% minimum solder coverage. | Product with Lead-free terminal: Dip pads in flux then dip in solder pot at 245 ± 5°C for 3 seconds. |
Resistance to Soldering Heat | No case deformation or change in appearance. | Flux should cover the whole of the sample before heating, then be preheated for about 2 minutes over temperature of 130 ~ 150°C. Immersing to 260 ± 5°C for 10 seconds. |
Vibration test | No case deformation or change in appearance. Δ L/L ≤10% |
Apply frequency 10 ~ 55Hz. 1.5mm amplitude in each of perpendicular direction for 2 hours. |
Shock resistance | Drop down with 981m/s² (100G) shock attitude upon a rubber block method shock testing machine, for 1 time. In each of three orientations. |
리플로우
The Condition Of Reflow (Recommendation):
코드
- 1R0