APPLICATIONS AUTOMOBILES
Résistance de précision en film mince 0,01 %, TC2ppm, wirebondale, anti-corrosion, MELF. Détection...
Lire la suiteInducteur SMD haute puissance, haute saturation, type plaqué argent, conception à faible coût, idéales pour les convertisseurs DC-DC, différentes tailles allant de petite taille de 3,5*3 à 10*9mm.
PCD Series0302 ±10% 27μH 0.76 Ω 0.405A
Taille | Tolérance | Inductance | Condition de test | DCR (Ω) max. | IDC (A) |
---|---|---|---|---|---|
0302 | ±10% | 27 | 1KHz, 0.25V | 0.76 | 0.405 |
Type | Tape Size | Parts Per Reel | |
---|---|---|---|
W | P | 13" | |
PCD0301 | 12 | 8 | 3000 |
PCD0302 | 12 | 8 | 2000 |
PCD0403 | 12 | 8 | 1500 |
PCD0502 | 12 | 8 | 2000 |
PCD0503 | 12 | 8 | 1500 |
PCD0504 | 12 | 8 | 1500 |
PCD0703 | 16 | 12 | 1000 |
PCD0705 | 16 | 12 | 1000 |
PCD1004 | 24 | 12 | 1000 |
PCD1005 | 24 | 12 | 500 |
PCD1006 | 24 | 12 | 500 |
General
Item | Specification |
---|---|
Shelf Storage conditions | Temperature range: 15 ~ 28°C; Humidity: < 80% relative humidity. Recommended product should be used within one year from the time of delivery. |
Environmental Test
Item | Specification | Test Conditions / Test Methods |
---|---|---|
High temperature Storage test | No case deformation or change in appearance. Δ L/L ≤10% |
Temperature 85 ± 2°C, Time: 48 ± 2 hours, Tested after 1hour at room temperature. |
Low temperature Storage test | Temperature -25 ± 2°C, Time: 48 ± 2 hours, Tested after 1hour at room temperature. |
|
Humidity test | Temperature 40 ± 2°C, 90~95% relative humidity Time: 96 ± 2 hours Tested after 1hour at room temperature. |
|
Thermal shock test | First -25°C 30minutes then 25°C 10 minutes last 85°C 30 minutes, as 1 cycle. Go through 5 cycles. Tested after 1 hour at room temperature. |
Mechanical Test
Item | Specification | Test Conditions / Test Methods |
---|---|---|
Solderability test | Terminal area must have 90% minimum solder coverage. | Dip pads in flux then dip in solder pot (SnCuNi) at 245 ± 5°C for 3 seconds. |
Resistance to Soldering Heat | No case deformation or change in appearance. | Flux should cover the whole of the sample before heating, then be preheated for about 2 minutes over temperature of 130 ~ 150°C. Immersing to 260 ± 5°C for 10 seconds. |
Vibration test | No case deformation or change in appearance. Δ L/L ≤10% |
Apply frequency 10 ~ 55Hz. 1.5mm amplitude in each of perpendicular direction for 2 hours. |
Shock resistance | Drop down with 981m/s² (100G) shock attitude upon a rubber block method shock testing machine, for 1 time. In each of three orientations. |
The Condition Of Reflow (Recommendation):
Résistance de précision en film mince 0,01 %, TC2ppm, wirebondale, anti-corrosion, MELF. Détection...
Lire la suiteInducteurs céramiques haute fréquence, de petite taille jusqu'à 01005. Film mince, multicouche, bobiné,...
Lire la suiteLe condensateur céramique multicouche offre une haute tension, haute fréquence, faible bruit, haute...
Lire la suite